Open the tab that includes the emulation view to display a 3-D emulation of your configured object and to visualize your object running virtually.
As an example, the figure illustrates the emulation view of a multi carrier track in the tab of the editor in EcoStruxure Machine Expert:
Legend item |
Description |
Refer to |
---|---|---|
1 |
The Settings link is used for configuring the emulation via and the OPC UA communication between and the controller. |
|
2 |
The Start Emulation and Stop Emulation buttons are used for starting and stopping the emulation. |
|
3 |
The View area displays a 3-D emulation of your configured object and for visualizing your object running virtually. |
Click the Settings link to open the Emulation Settings view of the logic motion controller device editor.
The Emulation Settings view is described in the
Element |
Description |
---|---|
Start Emulation |
Click the Start Emulation button to connect to the OPC UA server on the controller (via running in the background) and start the emulation of the object.
NOTE: For detailed steps and prerequisites, refer to Procedure for Starting the Emulation.
|
Stop Emulation |
Use this button to stop the emulation and disconnect from the OPC UA server on the controller. |
Step |
Action |
---|---|
1 |
Configure an OPC UA server on your controller and add code to your application for starting it.
NOTE: If the option is activated in the General Settings tab of the OPC UA Server Configuration of the PacDrive LMC controller, a user account needs to be configured in the device user management of the controller that is member of a group with access rights Modify and View to the OPC_UA runtime object
For information about starting an OPC UA server on a PacDrive LMC controller, refer to the OPC UA Server Configuration. |
2 |
In the Emulation Settings tab of the PacDrive LMC device editor, configure the IP address of the OPC UA server and the login mode.
NOTE: Activate the option Anonymous Login only in case the option was not activated in the General Settings tab of the OPC UA Server Configuration of the PacDrive LMC controller.
For further information, refer to the EcoStruxure Machine Expert Programming Guide. |
3 |
Verify that the Symbol Configuration object is part of the application and that the emulation data are selected. For further information, refer to the EcoStruxure Machine Expert Programming Guide. |
4 |
Download the application (including the OPC UA server in the Symbol Configuration) to the controller and start the application. |
5 |
In the emulation view, click the Start Emulation button. |
6 |
If the option General Settings tab of the OPC UA Server Configuration of the PacDrive LMC controller, the OPC UA Credentials dialog box opens. Enter the credentials of a user account that has been configured in the device user management of the controller (refer to step 1) and click OK to log in. is activated in the |
7 |
Accept the controller certificate. |
8 |
If the option General Settings tab of the OPC UA Server Configuration of the PacDrive LMC controller, you need to declare the certificate as trusted. is activated in the
NOTE: The certificate name is Machine Expert Twin@xxxx, where xxxx is the name of the client PC.
For further information, refer to Define Trusted Client Certificates. |
9 |
Once the certificate is in the trusted certificates list, click the Start Emulation button. |
The View area displays a 3-D emulation of your configured object and you can visualize your object running virtually.
Zooming, rotating, and moving the object in the View area:
Zooming: Use the mouse scroll wheel.
Rotating: Left-click and hold, then move the mouse.
Moving: Right-click and hold, then move the mouse.
For further information, refer to the EcoStruxure Machine Expert Twin online help.